25148
Industrial Power Supply, 90 ~ 264 VAC; 127 ~ 370 VDC

90 ~ 264 VAC; 127 ~ 370 VDC
Related Products
25148 Overview
Features
- Universal AC input/full range
- 3 pole AC inlet IEC320-C14
- Built-in active power factor controller function
- Industrial (-30°C to +70°C) operating temperature
- No load power consumption ≤0.15 Watts
- Energy efficiency Level VI
- Compliant with EIASA 2007/DoE, NRCan, AU/NZ MEPS, EU ErP and
- CoC Version 5
- Class 1 power (with earth pin)
- Short circuit/overload/over voltage/over temperature protection
- Fully enclosed 94V-0 flame retardant plastic case
- LED power on indicator
25148 Tech Specs
- 4-pin DIN plug (see plug assignment)
- UL1185 16AWG
- 48V (Output voltage set at point measure by plug terminal +50% load)
- 1.87A
- 0-1.87A
- 90W (max)
- 240mVp-p (max) (Measured at 20MHz by using a 12” twisted pair terminated with a 0.1uf &47uf capacitor)
- ±2.5% (Includes set up tolerance, line regulation, load regulation)
- ±1.0% (Line regulation is measured from low line to high line at rated load)
- ±2.5%
- 1000ms, 50ms/230VAC; 1000ms, 50ms/115VAC at full load (Length of setup time is measured at first cost start. Turning ON/OFF the power supply may lead to increase of the setup time)
- 20ms/230VAC typ; 20ms/115VAC at full load typical
- 90-264VAC, 127-370VDC (Derating may be needed under low input voltages. Check the derating curve for more details.)
- 47-63 Hz
- PF>0.91/230VAC typical; PF>0/95/115VAC at full load typical
- 91% typical
- 1.3A/115VAC typical; 0.6A/230VAC typical
- 70A/230VAC (max)
- 1mA/240VAC (max)
- I/P-O/P: 3KVAC, I/P-FG: 2KVAC. O/P-FG: 0.5KVAC
- I/P-O/P, I/P-FG, O/P-FG: 100M
- Ohms/500VDC/25°C/70%RH
- Overload: 110-150% rated output power (Hiccup mode, recovers automatically after fault condition is removed)
- Overvoltage: 105-135% rated output voltage (Shut down o/p voltage, re-power on to recover)
- Over Temperature: Shut down o/p voltage, re-power on to recover
- Width: 5.71” [145 mm]
- Depth: 2.36” [60 mm]
- Height: 1.26” [32 mm]
- Operating: -30°C to +70°C (See derating curve)
- Storage: -40°C to +85°C
- Humidity: 20% to 90% (non-condensing)
- 0.99 lbs. [0.45 kg]
- 348.7K hours min MIL-HDBK-217F (25°C)
- 10-500Hz, 2G 10min/1 cycle period for 60 min each
along X,Y,Z axes - Safety: UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS 14336, CCC Gb4943, PSE J60950-1, AS/NZS 60950.1 approved
- Emmisions: EN55022 class B, EN61000-3-2,3, FCC Part 15/CISPR22 class B, CNS13438 class B, GB9254, GB17625.1
- Immunity: EN61000-4-2,3,4,5,6,8,11 light industry level, criteria A
Connector
Cable
Output Voltage
Rated Current
Current Range
Rated Power
Ripple & Noise
Voltage Tolerance
Line Regulation
Load Regulation
Setup, Rise Time
Hold Up Time
Input Voltage
Input Frequency Range
Power Factor
Efficiency
AC Current
Inrush Current
Leakage Current
Withstand Voltage
Isolation Resistance
Protection
Dimensions
Environment
Weight
MTBF
Vibration
Certifications
25148 Resources
Application Spotlights
Videos
Press Releases
Case Studies
25148 Downloads
Note: Some Documentation may have Transition Networks named or pictured. Transition Networks was acquired by Lantronix in August 2021. Learn more about the acquisition here.
25148 Part Numbers
- Lantronix Worldwide Offices – Find an office in your region from our list of worldwide offices.
- Find a Lantronix Partner – Lantronix products are available from a variety of leading technology vendors.
25148 | 25148 |
90 ~ 264 VAC; 127 ~ 370 VDC |
||
Lantronix Part # | Name | Description | Order Now |
---|
Compatible Accessories
Lantronix Part # | Legacy Part # | Name | Description | Order Now |
---|---|---|---|---|
EO2PSE4052-111 | EO2Px Series | Ethernet Over 2-Wire Extender With PoE+(1) 10/100/1000Base RJ-45/SFP Combo Port + (1) 1000Base-T RJ-45 Port or 2-Wire Terminal Block | ||
EOCPD4020-110 | EOCPx Series | Ethernet Over Coax Extender With PoE+ (1) 100/1000Base RJ-45/SFP Port + (1) 1000Base Coax BNC Port |